Air conditioning installation in Brunswick starts with the house, not the brochure. Peak Air Conditioning Brunswick installs wall-mounted split systems, multi-head systems and ducted reverse cycle air conditioning across Brunswick and the inner north, from Victorian terraces off Sydney Road to new apartments. Each job begins with a room-by-room heat load check, so the system is sized for the space, insulation and glazing rather than guessed. The technician then plans where the indoor and outdoor units sit, how the pipework and drain run and what the electrical circuit needs. Refrigerant work is carried out under an ARC refrigerant handling licence, and every system is pressure tested, evacuated and commissioned before handover. Brands such as Daikin, Mitsubishi Electric, Fujitsu and Panasonic are fitted to the manufacturer's requirements. Call for a free written quote after inspection.
GET A FREE QUOTE
12
Heating and cooling services
13
Brunswick and nearby suburbs covered
Free
Written quote before work starts
7 days
Open 6am to 10pm
Air conditioning installation in Brunswick covers five main system types, and the right one depends on how many rooms need conditioning and how the house is built.
A wall-mounted split is one indoor head linked to one outdoor unit by refrigerant pipework. It suits a single living room or bedroom, with common sizes running from 2.5 kW for a small bedroom to 7 kW or more for an open-plan living area. Most are reverse cycle, heating in winter and cooling in summer, and single-room jobs are covered under split system installation.
A multi-head system runs two or more indoor heads from one outdoor unit. It suits a terrace with a narrow side path, because only one condenser needs a home, and each head is controlled separately.
A ducted system hides the indoor unit in the roof space and delivers air through ceiling vents to every room, with zoning so unused rooms can be switched off. It suits larger homes where wall-mounted heads are not wanted; see ducted air conditioning for options.
An evaporative cooler draws outside air through wet pads on the roof and pushes cooled air through ducts, with windows left open so the air can escape. It cools only and works best on dry hot days, and existing coolers are looked after through evaporative cooler service and repairs.
A ceiling cassette sits flush in the ceiling and spreads air in four directions, suiting shops, offices and large living areas. A floor console sits low on the wall, a good fit in a period room where a high-wall head would cut across a cornice.


Every installation follows the same four stages, from the first measurement to the final test run.
The technician measures each room and notes ceiling height, insulation, window size and orientation, then works out the heating and cooling load in kilowatts. An undersized unit runs flat out and still struggles on the hottest days, while an oversized one cycles on and off, wastes power and leaves the room clammy.
The indoor head is placed where air can spread across the room without blowing straight onto a bed or couch. The outdoor unit needs clear airflow, a solid base or wall brackets and access for future servicing, ideally away from a neighbour's bedroom window.
Insulated copper pipework links the two units, and the condensate drain is laid with a steady fall so water cannot pool or back up into the head. Larger units usually need a dedicated circuit, and that work is done by a licensed electrician to the Australian wiring rules, AS/NZS 3000.
Before any refrigerant is released, the brazed and flared joints are pressure tested with nitrogen and the lines are evacuated with a vacuum pump to remove air and moisture. The system is then run in both heating and cooling, with temperatures, drainage and controls checked before the owner is shown the remote and filters. The manufacturer warranty applies when the system is installed and commissioned to the manufacturer's requirements.
Brunswick's housing mix shapes almost every installation, from Victorian terraces to interwar and postwar homes and new apartments along Sydney Road.
Terraces and workers' cottages in Brunswick are often narrow, with solid brick walls, high ceilings and a long hallway running front to back. High ceilings add air volume, so sizing uses the room's full height rather than its floor area alone. Pipe runs are planned along the side wall or through the roof space to keep visible pipe cover off the original front rooms.
In an apartment, the outdoor unit usually sits on the balcony or a plant deck, and the pipe run has to stay within the lot. Most owners corporations require approval before anything is fixed to common property or changes the outside look of the building, so that approval should be in hand before the install is booked. The written quote sets out the unit position and pipe route for that application.
Parts of Brunswick sit under a heritage overlay in the Merri-bek planning scheme, where the street view of a period home is protected. The usual approach is to place the outdoor unit at the side or rear, out of sight from the street, and to keep pipework off the front facade. Where a visible position cannot be avoided, check with Merri-bek City Council whether a planning permit is needed.


Peak Air Conditioning Brunswick keeps installation simple: licensed technicians, a written price agreed in advance and a clean finish.
The Australian Refrigeration Council states that anyone who handles refrigerant or works on air conditioning equipment, including installing and commissioning it, must hold a refrigerant handling licence, known as ARCtick. Every split, multi-head and ducted install is carried out by a technician holding that licence.
After the inspection, the owner receives a written quote listing the unit, its capacity, the pipe run, any electrical work and removal of an old system. Nothing is added on the day without a conversation first.
Drop sheets go down before drilling, wall penetrations are sealed and outside pipe runs are finished in neat duct cover rather than taped insulation. Packaging and any old unit are taken away, and the work area is vacuumed before the technician leaves. Bookings run from 6am to 10pm, seven days, with same-day inspections where possible.
These are indicative Melbourne ranges from published guides, not a fixed price; a written quote is given after inspection.
Melbourne cost guides put a standard back-to-back install of a unit the owner has already bought at around $735 to $1,575 (whatsthedamage.com.au, November 2026). Supplied and installed, the same guide lists about $1,475 to $2,950 for a 3.5 kW unit and $2,300 to $4,725 for a 7 kW unit, while a two-head multi-split is listed at around $4,200 to $7,900.
For ducted reverse cycle, the same Melbourne guide lists about $8,400 to $14,700 for a three-bedroom home, or a single-storey four-bedroom home with good roof access. Larger, two-storey or zoned homes are listed at around $12,600 to $23,100.
The biggest factors are unit capacity, pipe run length, whether the outdoor unit sits on the ground, a wall bracket or the roof, and whether a new circuit is needed. A Melbourne installer's calculator adds roughly $450 where licensed electrical work is needed and about $250 to remove an old unit (Climate Control Solutions, July 2026).
The Victorian Energy Upgrades program lists discounts of up to $1,610 for replacing a non-ducted gas heater with reverse cycle, and up to $5,530 when removing or replacing a ducted gas heater. The product must be approved under the program and carry a minimum five-year warranty, so eligibility is confirmed before the quote is finalised.


Most Brunswick homes suit either split systems or ducted, and the choice comes down to running costs, comfort and how the system looks and sounds.
Split systems condition only the rooms in use, which keeps running costs low in a smaller home or apartment. Ducted costs more to run if every zone is left on, but zoning shuts off empty rooms. Against gas, the Victorian Energy Upgrades program estimates savings of up to $1,140 a year when a ducted gas heater is replaced with efficient reverse cycle air conditioning.
Ducted gives an even temperature through the whole house from one controller, with zones for living areas and bedrooms. Split systems give room-by-room control, which suits households where people prefer different temperatures, and a multi-head system adds rooms without a second outdoor unit.
With ducted, the only visible parts indoors are the vents and a wall controller, and the compressor sits outside. A split puts a head on the wall of each room, which some owners of period homes would rather avoid in a front room with original detail. Outdoor unit placement usually matters more for noise than the brand, so the condenser is kept away from bedrooms and boundary windows.

A technician visits to look at the rooms, walls, roof space and outdoor unit position, checks the heating and cooling load, and provides a free written quote before any work starts.

The agreed work is carried out by refrigerant-licensed technicians, with pipe runs kept neat, drains fall-tested and any gas or electrical work done by licensed trades.

The system is pressure tested, commissioned and run in heating and cooling mode, then the controls, filters and manufacturer warranty requirements are explained at handover.
Melbourne cost guides put a standard back-to-back split install at around $735 to $1,575 when the unit is already bought, or about $1,475 to $2,950 supplied and installed for a 3.5 kW unit. Ducted reverse cycle for a three-bedroom home is listed at about $8,400 to $14,700. The final price depends on capacity, pipe run and electrical work, and a written quote is given after inspection.
A back-to-back split system on an outside wall is usually a same-day job. Multi-head systems and longer pipe runs take longer. Ducted systems usually need more than one day, because ducts and vents are run through the roof space. The written quote sets out the expected timeframe before the work is booked.
Yes. The Australian Refrigeration Council requires anyone who handles refrigerant, including installing and commissioning air conditioning, to hold a refrigerant handling licence, known as ARCtick. A new electrical circuit must be installed by a licensed electrician. Disconnecting an old gas heater needs a licensed gasfitter registered with the Building and Plumbing Commission.
The right size comes from a heat load check of each room: floor area, ceiling height, insulation, window size and which way the room faces. Split systems commonly run from 2.5 kW for a small bedroom to 7 kW or more for an open-plan living area. High-ceilinged terrace rooms need more capacity than their floor area suggests.
Yes, in most cases. The outdoor unit usually goes on the balcony and the pipe run stays inside the apartment. Owners corporation approval is usually needed before anything is fixed to common property or changes the building's outside appearance. Peak Air Conditioning Brunswick puts the unit position and pipe route in writing so the approval can be sought before booking.
Split systems suit apartments, units and homes where only a few rooms need conditioning, and they cost less to install. Ducted suits larger homes where an even temperature in every room and hidden equipment matter more than the upfront cost. A multi-head system is a common middle ground in Brunswick terraces.