Air conditioning repair in Brunswick starts with finding the actual fault, not guessing at it. Peak Air Conditioning Brunswick repairs split systems and ducted reverse cycle air conditioning in the terraces, workers' cottages, postwar homes and apartments of Merri-bek. Typical jobs include a system that will not cool or heat, water dripping from the indoor head, an error code flashing on the display, a rattle or burning smell, and a unit that trips the power. The technician tests the system, explains the fault and gives a written price before any part is fitted. Refrigerant leaks are found and sealed before a regas, and older R22 systems get a straight repair or replace answer. Call to book a repair visit between 6am and 10pm, seven days, with same-day attendance where possible.
GET A FREE QUOTE
12
Heating and cooling services
13
Brunswick and nearby suburbs covered
Free
Written quote before work starts
7 days
Open 6am to 10pm
Peak Air Conditioning Brunswick
Most repair calls in Brunswick come down to a short list of faults, each with a few likely causes. Evaporative coolers are a different system with their own pumps and pads, and are covered on the evaporative cooler service and repairs page.
A split system has an indoor head on the wall and an outdoor condenser. A fault can sit in either half, so both units, the refrigerant pipes and the interconnecting cable between them are tested before anything is replaced.
A ducted system adds a roof-space or underfloor indoor unit, a duct network, zone dampers and a wall controller. Many ducted faults sit outside the unit itself: a split or collapsed duct, a stuck zone motor or a choked return air filter can starve rooms of air while the unit runs normally.
A system that runs but will not cool or heat usually has a clogged filter, a dirty outdoor coil, a low refrigerant charge, a failed fan or a wrong mode setting. On a reverse cycle unit that cools but will not heat, the reversing valve or its solenoid coil is a common cause.
Water running down the wall below the indoor head usually means the condensate drain is blocked with dust and slime, the drain line has lost its fall or the drain tray has cracked. A coil that has iced up from low refrigerant or a choked filter can also melt and overflow the tray.
Daikin, Mitsubishi Electric, Fujitsu and Panasonic units each use their own fault codes or blinking light patterns on the indoor head. The code narrows the search, and the technician confirms it with electrical tests rather than ordering parts on the code alone.
Rattling and buzzing usually trace back to a loose panel, a worn fan bearing or a capacitor that is failing. A musty smell points to mould on the coil or a stagnant drain tray, while a burning or electrical smell means the system should be switched off at once and checked.
A unit that trips the circuit breaker or safety switch can have a shorted compressor winding, a failed fan motor, water in the wiring or a damaged control board. A system that will not start at all may have a blown fuse on the board, a failed outdoor contactor or a communication fault between the two units.


Peak Air Conditioning Brunswick
A repair visit follows three steps, so the cost is known before work starts and the fix is proven before the technician leaves.
The technician reads any stored fault code, then checks the power supply, filters, coils, fans, drain and refrigerant pressures. Electrical parts are tested with a multimeter, so a failed capacitor or board is confirmed rather than assumed. An intermittent fault is chased by running the system through cooling and heating until it shows.
Once the fault is found, the cause is explained in plain terms and a written price is given for the part and the labour. Nothing is fitted until that price is approved. If the repair would be poor value against a new unit, that is said at this stage too.
After the fix, the system runs in both modes while the technician checks the air temperature leaving the indoor unit, the fan speeds, the drain flow and the outdoor unit. Anything closer to routine upkeep, such as a heavily soiled coil, is noted for a later air conditioning service. For a breakdown that cannot wait for a booked visit, the emergency air conditioning repair page explains the urgent option.
Peak Air Conditioning Brunswick
Refrigerant runs in a sealed loop and is not used up like fuel, so a system that is short of gas has a leak.
Low refrigerant shows up as weak cooling or heating, ice on the indoor coil or on the copper pipes at the outdoor unit, a hissing or bubbling sound, and a system that runs for long periods without reaching the set temperature.
Topping up a leaking system only buys time until the gas escapes again. The technician checks the flare joints, service valves and coils with electronic leak detection and bubble solution, then remakes the joint or repairs the part. The circuit is pressure tested with nitrogen and vacuumed to remove air and moisture before any refrigerant goes back in. Flare nuts behind the indoor head and joints at the outdoor unit are common leak points.
Aircon regassing means recharging the system with the refrigerant named on its compliance plate, commonly R32 or R410A, weighed in to the manufacturer's stated charge. Charging by weight matters, because both overcharging and undercharging reduce output and strain the compressor. Recovered refrigerant is never vented, and the work is done under an ARC refrigerant handling licence.


Peak Air Conditioning Brunswick
When a part has failed, it is replaced with one matched to the model number, and the cause of the failure is checked.
A capacitor gives the compressor and fan motors the electrical kick they need to start. A swollen or weak capacitor leaves a fan that hums but will not spin, or an outdoor unit that clicks and stops. Fan motors wear out at the bearings or burn out, and a failed indoor or outdoor fan stops the system moving heat.
The compressor pumps refrigerant around the system and is the most expensive part to replace. Before a compressor is condemned, the capacitor, contactor, wiring and refrigerant charge are all checked, because each can make a sound compressor look dead.
The printed circuit board (PCB) runs the system, and temperature sensors called thermistors report what the coils and the room are doing. Power surges, moisture and age can kill a board, while a faulty sensor can cause false error codes, constant defrosting or a unit that shuts off early. Sensors are quick to test and inexpensive to replace, so they are ruled out before a board is ordered.
Where an indoor unit cannot drain by gravity, such as a head on an internal wall of an apartment, a small condensate pump lifts the water out. A failed pump or a blocked or sagging drain line is the usual cause of water leaks, and the line is flushed, re-graded or replaced along with the pump.
Peak Air Conditioning Brunswick
Peak Air Conditioning Brunswick repairs split and ducted systems across the inner north, from Sydney Road terraces to new apartment blocks, with the same process on every job. Outdoor units here often sit in the side passages of Victorian and Edwardian terraces or on apartment balconies and rooftops, and access is planned before the visit. Repairs cover Daikin, Mitsubishi Electric, Fujitsu, Panasonic and other major brands, with a written price before work and bookings from 6am to 10pm, seven days.
Anyone who handles refrigerant or works on refrigeration and air conditioning equipment must hold a refrigerant handling licence, issued through the Australian Refrigeration Council (ARCtick). Every leak repair, regas and part replacement on the sealed circuit is carried out under that licence, with refrigerant recovered rather than released. Work on the house wiring is left to a licensed electrician.


Peak Air Conditioning Brunswick
Repair cost depends on the fault, the part and how hard the units are to reach, so a written quote is given after inspection. The figures below come from published Victorian and Melbourne cost guides and are indicative, not a fixed price list.
The Quote Yard's 2026 Victorian estimates put a standard-hours callout and diagnosis at around $120 to $250, with a band of $120 to $220 for Melbourne's northern suburbs. The same guide notes that the fee is usually credited against the repair, and lists labour at $110 to $180 an hour with a minimum charge.
The Quote Yard lists fitted Victorian costs of about $180 to $400 for a capacitor, $200 to $450 for a contactor, $450 to $900 for a fan motor, $500 to $1,400 for a control board, $700 to $1,500 for a reversing valve and $1,400 to $2,800 for a compressor. It notes that most repairs land between $300 and $900.
Because a regas should follow a leak repair, the two are best priced as one job. The Quote Yard puts a leak repair plus regas at around $400 to $900, and whatsthedamage lists a major repair or regas in Melbourne at roughly $315 to $1,250. The final figure depends on where the leak is, how much refrigerant the system holds and which refrigerant it uses.
Peak Air Conditioning Brunswick
When a repair quote is large, the better answer is sometimes a new system, and three factors decide it.
As a rough guide only, a well-maintained split system often gives 10 to 15 years of service, and a unit near the end of that span with a major fault is a candidate for replacement. A younger unit with one failed part is usually worth repairing. A system that has needed several repairs in a few seasons is likely to keep needing them.
Compare the repair price with the cost of a new unit of the same size. Whatsthedamage puts a supplied and installed 3.5 kW split system in Melbourne at around $1,475 to $2,950, so a $1,400 to $2,800 compressor on an ageing 3.5 kW unit is often poor value. On a ducted system, where the same guide puts a typical three-bedroom Melbourne install at around $8,400 to $14,700, a major repair more often makes sense. New room systems are covered on the split system installation page.
Many older systems run on R22, a refrigerant that Australia has been phasing out under its ozone protection rules. R22 supply is now limited and costly, and a newer refrigerant cannot simply be added to an R22 circuit. A leaking or failed R22 unit is often better replaced, while a sound R22 unit with a minor electrical fault, such as a capacitor, can still be repaired.


A technician visits to look at the rooms, walls, roof space and outdoor unit position, checks the heating and cooling load, and provides a free written quote before any work starts.

The agreed work is carried out by refrigerant-licensed technicians, with pipe runs kept neat, drains fall-tested and any gas or electrical work done by licensed trades.

The system is pressure tested, commissioned and run in heating and cooling mode, then the controls, filters and manufacturer warranty requirements are explained at handover.
Published Victorian cost guides put a standard-hours callout and diagnosis at around $120 to $250, usually credited against the repair. The Quote Yard notes that most repairs land between $300 and $900, with a compressor at the top end at $1,400 to $2,800. A written price is given after diagnosis and before any work starts.
The usual causes are a blocked filter, a dirty outdoor coil, low refrigerant from a leak, a failed fan or capacitor, or the system set to the wrong mode. Check that the remote is set to cool, the filters are clean and the outdoor unit is not hemmed in by plants or stored items. If it still blows warm air, switch it off and book a repair, as running short of refrigerant can damage the compressor.
Water from a split system's indoor head usually means the condensate drain line is blocked, kinked or has lost its fall, or the drain tray is cracked. A dirty filter or low refrigerant can also freeze the coil, and the melting ice then overflows the tray. The technician clears or replaces the drain and fixes whatever caused the ice.
The Quote Yard puts a leak repair plus regas at around $400 to $900 in Victoria, and hipages lists replacing refrigerant alone at roughly $160 to $400 nationally. A regas without fixing the leak is poor value, because the gas escapes again. Peak Air Conditioning Brunswick quotes in writing once the leak has been found.
It depends on the age of the unit, the fault and the refrigerant it uses. A minor repair such as a capacitor or a sensor is usually worth doing, even on an older system. A failed compressor or a leaking R22 system near the end of its life is often better replaced, because a new split system can cost little more than the repair.
Peak Air Conditioning Brunswick repairs split and ducted systems from the major brands sold in Australia, including Daikin, Mitsubishi Electric, Fujitsu, Panasonic, Samsung, LG, Toshiba and ActronAir. Parts are sourced to suit the model number on the unit's compliance plate. Parts supply for discontinued models is checked before a repair is quoted.